RadiaScan Revision History


1.23.06 (Jul 14, 2022)

Added [Firmware]: Support for the RadiaScan-801M model (firmware version 4.20).

1.23.05 (Apr 6, 2021)

Added documentation for the RadiaScan program.

1.23.04 (Jan 20, 2021)

Fixed: When selecting "Sievert" units in the shell, the Log window displayed the result values in mR.

1.23.03 (Nov 20, 2020)

Changed [Firmware]: Minor improvements related to mass production support.

Changed [Firmware]: Firmware version 4.20.

1.23.02 (Jul 10, 2020)

Added [Firmware]: Alarms are issued also when the device is turned off with the button and at the same time performs a scheduled measurement.

Changed [Firmware]: Display contrast is set in steps from -3 to +3.

Changed [Firmware]: Firmware version 4.19.

1.23.01 (Jun 15, 2020)

Fixed: Error when opening the graphs window configuration dialog if there is no log records of measurement results on a schedule.

1.23.00 (Apr 21, 2020)

Added [Firmware]: Ukrainian language on device.

Added [Firmware]: Quick switch between GAMMA and SEARCH modes by long pressing the "Left" button.

Added [Firmware]: Turning on/off battery charging by long pressing the "Right" button.

Changed [Firmware]: Firmware version 4.18.

Added: Graphical display of the results of measurements made on schedules.

1.22.01 (Feb 5, 2020)

Added [Firmware]: French language on device.

Changed [Firmware]: Firmware version 4.17.

1.22.00 (Jan 13, 2020)

Fixed [Firmware]: Sometimes the device settings were spontaneously reset to the factory settings, including the dose value being lost.

Fixed [Firmware]: Filtering options used to view log entries were not saved.

Changed [Firmware]: Firmware version 4.16.

Added: Ability to set a comment to more than log record simultaneously.

1.21.00 (Nov 18, 2019)

Added [All]: Data obtained in the SEARCH and DETECTION modes can be displayed in cps units.

Fixed [Firmware]: After reset of the device options to factory settings the time in the device clock always changed.

Fixed [Firmware 701/501]: Random error is now estimated with a confidence level of 0.95 (was 0.9).

Changed [Firmware]: Firmware version 4.15.

1.20.01 (Jul 12, 2019)

Fixed [Firmware]: The daylight saving time on/off function did not work properly.

Changed [Firmware]: Firmware version 4.14.

1.20.00 (Jan 16, 2019)

Added [Firmware]: Support for new RadiaScan-801 model.

Fixed [Firmware]: The device tried to charge the batteries when non-rechargeable batteries were selected in the device settings.

Fixed [Firmware]: Beeps were emitted by pressing the buttons when the device was turned off and powered from an external source.

Changed [Firmware]: Firmware version 4.13.

1.19.00 (Mar 6, 2018)

Changed: Operation Manual.

Added [Firmware]: Battery charge indication (see p.1.7.2 and p.1.8.1 of the Operation Manual).

Added [Firmware]: Forcing the battery to stop charging by pressing the "Right" button for a long time.

Fixed [Firmware]: Switching the device on/off by pressing the "Power" button does not complete the process of charging the batteries now.

Fixed [Firmware]: The spontaneous switch-off of the device during wake-up of the display, which occurred when use of discharged batteries, is eliminated now.

Changed [Firmware]: The conditions for starting the batteries charging process are changed (see p. 2.16 of the Operation Manual).

Changed [Firmware]: Firmware version 4.12.

1.18.01 (Oct 30, 2017)

Changed: Information about calibration of the device's built-in clock is placed into a disk file instead of registry to avoid problems for non-admin Windows users.

1.18.00 (Oct 24, 2017)

Added [Firmware]: Support for new models (RadiaScan-501A and RadiaScan-701A) with embedded recharging unit for NiMH batteries.

Changed: Operation manual.

Changed [Firmware]: Firmware version 4.11.

1.17.01 (Sep 12, 2017)

Improved [Firmware]: The device power consumption is decreased during power on procedure.

Changed [Firmware]: Firmware version 4.10.

1.17.00 (Aug 24, 2017)

Changed [Firmware]: The default display contrast value is changed to 20%.

Changed [Firmware]: Pressing any button briefly (by 3 sec.) increases the brightness of the display.

Changed [Firmware]: Firmware version 4.09.

1.16.01 (Jan 9, 2017)

Fixed [Firmware]: The bug that disabled the clicking sound in standalone mode.

Changed [Firmware]: Firmware version 4.08.

1.16.00 (Dec 30, 2016)

Fixed[Software]: Data sorting bug in the log columns.

Fixed[Software]: In case of considerable dose rate sound clicks were heard as a single tone.

Added[Firmware]: View of the measurement results done in the SEARCH mode.

Fixed[Firmware]: The bug that disabled the device display in case of USB connection.

Fixed[Firmware]: The dose rate parameters displayed incorrectly after turning display off by the key and the further turning on (in stand alone mode).

Changed[Firmware]: Firmware version 4.07.

1.15.00 (Dec 21, 2016)

Added[SW RadiaScan]: In case of multiple devices connected to your PC at the same time you can switch to any of the connected devices.

Added[SW RadiaScan]: If you use multiple devices you may view the log separately for every device.

Added[SW RadiaScan]: The possibility to save/restore device options to/from the file on your PC.

Added[Firmware]: The possibility to view the log on the screen of the device.

Added[Firmware]: The RTC calibration feature. Use the "Real time clock calibration" option in the "Scripts" menu of the RadiaScan software.

Added[Firmware]: You can turn the device display off in "Gamma" and "Search" modes by means of long pressing "DOWN" button on the keyboard.

Added[Firmware]: A number of Date and Time display formats.

Added[Firmware]: Alarm sound on the event of measured values expand beyond the permissible range.

Added[Firmware]: Continuous alarm sound until pressing any key.

Changed[Firmware]: Nonsignificant zeros of the measured values are not displayed now.

Changed[Firmware]: The maximum sampling time in the "Search" mode increased to 60 sec from 19 sec.

Changed[Firmware]: Firmware version to 4.06.

1.14.00 (Aug 30, 2016)

Added: Support for the board version ASE.02.101.01.07.

Changed: Firmware version 4.05.

1.13.00 (Nov 30, 2015)

Fixed: Some English menu items and text messages on the device.

Added: English version of the User's Manual.

Added: Saving the device log to csv file for Microsoft Excel.

Added: The device log can be erased from the RadiaScan application.

Added: Capability of restarting the dose accumulation in GAMMA mode from the RadiaScan application with clicking the "Restart measurement" button in the Dose mode.

Added: Displaying the device screen image in the RadiaScan application when the screen power is off.

Added: The "Frame Number" column in the Device Log window.

Added: Capability of adding/editing comments to the records in the Device Log window.

Changed: Firmware version 4.04.

1.12.00 (Oct 12, 2015)

Fixed: Some English menu items and text messages on the device.

Added: Support for the v3 device modification (board v. ASE.02.101.01.06).

Changed: Firmware version 4.03.

Changed: Firmware loader v. 3.21 for v3 modification.